We Never Stop Until We Win, Join Us

Oklahoma Residential Roofing Codes

Oklahoma regulations are primarily based on the International Residential Code (IRC) 2018. Below are the specific section numbers and local amendments you must know to avoid costly repairs and safety hazards.

Why This Matters

Ignoring these codes isn’t just illegal, it leads to costly mistakes and safety hazards. Oklahoma primarily follows the International Residential Code (IRC) 2018, with specific amendments for our unique climate.

Key Oklahoma Modifications

01

Ice Barriers (Section 905.1.2)

  • Must extend 24" inside exterior wall line.
  • 36" extension if slope > 67%.

OK Specific: 36" barrier required in all valleys & slope changes.

02

Drip Edges (Section R905.2.8.5)

Generally required at eaves/rakes, BUT Oklahoma allows an exception if:

  • A 1x2 inch shingle mold is used.
  • Starter shingles extend 1/4" to 1" beyond fascia.
03

Roof Decks (Section R905.2.1)

"Solidly Sheathed" is strictly defined as sawn lumber or structural panels with:

  • No Gaps
  • No Rot
  • No Warping

Specific Material Codes:

  • Clay/Concrete: R905.3.1
  • Metal Tile: R905.4.1
Trifecta Roofing and Restoration
triangle white
IRC 2018 / OK Amendments

Re-Covering Restrictions

A complete tear-off is mandatory if:

  • Existing roof is water-soaked or deteriorated.
  • Material is slate, clay, or asbestos-cement.
  • Roof has 2+ layers of any material.

Oklahoma Exclusive

The "One Layer" Limit

If the existing roof has one or more layers of asphalt shingles, you cannot add another layer. You must tear off.

Section R905.2

Asphalt Shingle Standards

Slope

Section R905.2.2

Minimum: 2:12
2:12-4:12 requires double underlayment

Underlayment

Section R905.2.3

Mandatory
> 4:12 = 1 Layer
2:12 to 4:12 = 2 Layers

Material

Section R905.2.4

Must comply with ASTM D3462
High wind (>110mph) needs ASTM D7158/D3161

Fasteners

Section R905.2.2

Corrosion-resistant nails only
Min penetration: ¾ inch or through deck

Water Management Essentials

Flashing

Section R903.2

Corrosion-resistant at all intersections.

Crickets

Section R903.2.2

Required for chimneys > 30 inches wide.

Coping

Section R903.3

Non-combustible weather-resistant caps.

Drainage

Section R903.4

Overflow drains required for internal systems.

Get a Free Consultation

Contact Us Today


    Trusted Best Company

    We're Raising The Roof On Roofing and Siding Standards

    Request your free, no-obligation roof or siding inspection today. Simply fill out the form and we’ll reach out fast, listen to your needs, and get your project started with trusted local experts. Secure, simple, and stress-free.

    5409de9ddff83e8d71a88e79e0117eb8 1