We Never Stop Until We Win, Join Us

Oklahoma Residential Roofing Codes

Oklahoma regulations are primarily based on the International Residential Code (IRC) 2018. Below are the specific section numbers and local amendments you must know to avoid costly repairs and safety hazards.


    Why This Matters

    Ignoring these codes isn’t just illegal, it leads to costly mistakes and safety hazards. Oklahoma primarily follows the International Residential Code (IRC) 2018, with specific amendments for our unique climate.

    Key Oklahoma Modifications

    01

    Ice Barriers (Section 905.1.2)

    • Must extend 24" inside exterior wall line.
    • 36" extension if slope > 67%.

    OK Specific: 36" barrier required in all valleys & slope changes.

    02

    Drip Edges (Section R905.2.8.5)

    Generally required at eaves/rakes, BUT Oklahoma allows an exception if:

    • A 1x2 inch shingle mold is used.
    • Starter shingles extend 1/4" to 1" beyond fascia.
    03

    Roof Decks (Section R905.2.1)

    "Solidly Sheathed" is strictly defined as sawn lumber or structural panels with:

    • No Gaps
    • No Rot
    • No Warping

    Specific Material Codes:

    • Clay/Concrete: R905.3.1
    • Metal Tile: R905.4.1
    Trifecta Roofing and Restoration
    triangle white
    IRC 2018 / OK Amendments

    Re-Covering Restrictions

    A complete tear-off is mandatory if:

    • Existing roof is water-soaked or deteriorated.
    • Material is slate, clay, or asbestos-cement.
    • Roof has 2+ layers of any material.

    Oklahoma Exclusive

    The "One Layer" Limit

    If the existing roof has one or more layers of asphalt shingles, you cannot add another layer. You must tear off.

    Section R905.2

    Asphalt Shingle Standards

    Slope

    Section R905.2.2

    Minimum: 2:12
    2:12-4:12 requires double underlayment

    Underlayment

    Section R905.2.3

    Mandatory
    > 4:12 = 1 Layer
    2:12 to 4:12 = 2 Layers

    Material

    Section R905.2.4

    Must comply with ASTM D3462
    High wind (>110mph) needs ASTM D7158/D3161

    Fasteners

    Section R905.2.2

    Corrosion-resistant nails only
    Min penetration: ¾ inch or through deck

    Water Management Essentials

    Flashing

    Section R903.2

    Corrosion-resistant at all intersections.

    Crickets

    Section R903.2.2

    Required for chimneys > 30 inches wide.

    Coping

    Section R903.3

    Non-combustible weather-resistant caps.

    Drainage

    Section R903.4

    Overflow drains required for internal systems.

    Get a Free Consultation

    Contact Us Today


      Trusted Best Company

      We're Raising The Roof On Roofing and Siding Standards

      Request your free, no-obligation roof or siding inspection today. Simply fill out the form and we’ll reach out fast, listen to your needs, and get your project started with trusted local experts. Secure, simple, and stress-free.

      5409de9ddff83e8d71a88e79e0117eb8 1